- Date
- 07/29/2021
- W/O
- 901971
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00005
- PipeID
- P00087
- Time
- 10:13 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9204
- Sewer Name
- 08 EAST ROAD TRUNK
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901971_TV08112_JUL2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 15 in.
- Upstream MH
- 08 0217
- Downstream MH
- 08 0216
- Dir. of Survey
- Downstream
- Length Surveyed
- 349.6 ft.
- Total Length
- 349.6 ft.
- Structural Index
- 4
- Structural Quick
- 4M00
- Structural Rating
- 276
- O&M Index
- 2
- O&M Quick
- 412Y
- O&M Rating
- 268
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 544
Pipe schematic from manhole 08 0217 to 08 0216 Observation photos (4)

4.8 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

4.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

33.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

349.6 ft. - General Observation - COCKROACHES IN MANHOLE