Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2021, 02:51 PM
  • 29 0517_29 0516A_07282021_075718.mp4

Date
07/28/2021
W/O
901941
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01106
PipeID
P24567
Time
7:51 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9088
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_901941_TV29072_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0517
Downstream MH
29 0516A
Dir. of Survey
Downstream
Length Surveyed
64.4 ft.
Total Length
64.4 ft.
Structural Index
3
Structural Quick
3A00
Structural Rating
36
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
36
Pipe schematic from manhole 29 0517 to 29 0516A
MH: 29 0517MH: 29 0516Adownstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 05170 ft. MWM - Water Mark, 5 %of cross sectional area4.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"28.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.4 ft. ACOM - Cleanout Mainline, Survey Ends - 29 0516A64.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
0AMH29 0517
64.4ACOM29 0516A
28.6TF
64.4CM
26.3TF
0MWM
4.6CM

Properties (7)

additional_info
630070072821051
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-07-28T07:51:46-07:00
documentation
PROPIPE
is_lateral_inspection
false