Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2021, 05:15 AM
  • B 0736_B 0735_07272021_223021.mp4

Date
07/27/2021
W/O
901464
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00111
PipeID
P09203
Time
10:15 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9104
Sewer Name
B JOINT OUTFALL B - UNIT 8H
City
DUARTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_901464_TV22165_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
21 in.
Upstream MH
B 0736
Downstream MH
B 0735
Dir. of Survey
Downstream
Length Surveyed
234.6 ft.
Total Length
234.6 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
138
Pipe schematic from manhole B 0736 to B 0735
MH: B 0736MH: B 0735downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK CAPPED0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - B 07365.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start69.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"110.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"130.7 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"174.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"203.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES232.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish234.6 ft. AMH - Downstream Manhole, Survey Ends - B 0735234.6 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    110.8 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    130.7 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    203.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MWL
234.6AMHB 0735
0MWM
232.3CM
203.9FL
5.7CM
0MGOCONNECTION AT MH 9 OCLOCK CAPPED
0MGOCONNECTION AT MH, 3 O'CLOCK
110.8TBA
174.1TF
234.6MGOCONNECTION AT MH, 3 O'CLOCK
130.7TBA
69.8TF
0AMHB 0736

Properties (7)

additional_info
630075072721201
custom_field_three
FRACTURES, CRACKS
custom_field_two
3
customer
1
datetime
2021-07-27T22:15:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false