- Date
- 07/28/2021
- W/O
- 901369
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00700
- PipeID
- P14781
- Time
- 9:55 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9201
- Sewer Name
- 18 SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901369_TV18118_JUL2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 18 0933
- Downstream MH
- 18 0932
- Dir. of Survey
- Downstream
- Length Surveyed
- 86.1 ft.
- Total Length
- 86.1 ft.
- Structural Index
- 3
- Structural Quick
- 5141
- Structural Rating
- 57
- O&M Index
- 2
- O&M Quick
- 412B
- O&M Rating
- 36
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 93
Pipe schematic from manhole 18 0933 to 18 0932 Observation photos (6)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

6.9 ft. - Hole, from 03 to 05 o'clock, within 8 inches of joint: YES

7.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

86.1 ft. - General Observation - COCKROACHES IN MANHOLE