Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 7, 2014, 08:10 AM
  • 14 0928_14 0927_07112014_001724.mp4

Date
11/07/2014
W/O
0459312
Weather
Dry
Operator/Surveyor
C. DEHNER
Sewer ID
Z00949
PipeID
P22912
Time
12:10 AM
Certificate
U-912-15963
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1633
Sewer Name
14 TRUNK "F" RELIEF, SECTION 2
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
06
Purpose
Routine Assessment
Project
WO_0459312_TV14052_2014October
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
14 0928
Downstream MH
14 0927
Dir. of Survey
Downstream
Length Surveyed
112.1 ft.
Total Length
112.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3C00
O&M Rating
66
Overall Index
3
Overall Quick
Overall Rating
66
Pipe schematic from manhole 14 0928 to 14 0927
MH: 14 0928MH: 14 0927downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 09280 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start111.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish112.1 ft. MGO - General Observation - Connec, @ Mh, 9 O' Clock. Active112.1 ft. AMH - Downstream Manhole, Survey Ends - 14 0927

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
111.8DAGS
112.1MGOConnec, @ Mh, 9 O' Clock. Active
0AMH14 0928
2.4DAGS
112.1AMH14 0927
0MWM
0MWL

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2014-11-07T00:10:09-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
20000114