Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2014, 11:46 AM
  • 32 1180_32 1179_10122014_041306.mpg

Date
12/10/2014
W/O
453976
Weather
Dry
Operator/Surveyor
C. DEHNER
Sewer ID
Z00839
PipeID
P19634
Time
3:46 AM
Certificate
U-912-15963
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2066-SC189993
Sewer Name
32 SAN FERNANDO ROAD TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
07
Purpose
Routine Assessment
Project
WO_453976_TV32022_2014DecemberPackage10
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
32 1180
Downstream MH
32 1179
Dir. of Survey
Downstream
Length Surveyed
553.3 ft.
Total Length
553.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2U00
O&M Rating
218
Overall Index
2
Overall Quick
Overall Rating
218
Pipe schematic from manhole 32 1180 to 32 1179
MH: 32 1180MH: 32 1179downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 11800 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start94.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"135.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"211.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"251.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"328.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"373.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"435.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"496 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"547.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"550.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish553.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1179

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    7 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0AMH32 1180
435.1TFC
328.2TFC
135.3TF
0MWL
7DAGS
373.9TFC
0MWM
553.3AMH32 1179
251.9TFC
211.4TFC
496TFC
547.1TFC
550.3DAGS
94.8TFC

Properties (6)

custom_field_two
CR-5
customer
LACSD
datetime
2014-12-10T03:46:20-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
19740129