Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 2, 2014, 09:17 AM
  • 14 0850_14 0849_02122014_013451.mp4

Date
12/02/2014
W/O
0459292
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00950
PipeID
P21429
Time
1:17 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1686-SC189310
Sewer Name
14 TRUNK "F" RELIEF, SECTION 3
City
LANCASTER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_0459292_TV14051_2014October
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
14 0849
Downstream MH
14 0850
Dir. of Survey
Upstream
Length Surveyed
327.8 ft.
Total Length
327.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 14 0849 to 14 0850
MH: 14 0849MH: 14 0850upstream0 ft. AMH - Upstream Manhole, Survey Ends - 14 0850 (01:33)327.8 ft. AMH - Downstream Manhole, Survey Begins - 14 0849 (01:17)327.8 ft. MWL - Water Level, 20 %of cross sectional area327.8 ft. MWM - Water Mark, 40 %of cross sectional area

Observation photos (1)

  • Downstream Manhole, Survey Begins - 14 0849 (01:17)

    0 ft. - Downstream Manhole, Survey Begins - 14 0849 (01:17)

Observations (4)

DistanceCodeObservation
0AMH14 0849 (01:17)
0MWL
327.8AMH14 0850 (01:33)
0MWM

Properties (6)

custom_field_two
CR 4
customer
LACSD
datetime
2014-12-02T01:17:32-08:00
documentation
PRO-PIPE
is_lateral_inspection
false
year_laid
19971030