- Date
- 12/11/2014
- W/O
- 453984
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z01067
- PipeID
- P23354
- Time
- 3:12 AM
- Certificate
- U507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K1697-SC189321
- Sewer Name
- 14 TRUNK "E" REPLACEMENT, SECTION 1
- City
- LANCASTER, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO#_453984_TV14026_December#6
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 14 0859
- Downstream MH
- 14 0858A
- Dir. of Survey
- Downstream
- Length Surveyed
- 56.2 ft.
- Total Length
- 56.2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole 14 0859 to 14 0858A Observation photos (3)

4.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

52.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

56.2 ft. - Downstream Manhole, Survey Ends - 14 0858A (03:18)