Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2014, 10:50 AM
  • 14 0153A_14 0153_20141204_Manual.mp4

Date
12/04/2014
W/O
0459268
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00584
PipeID
P18190
Time
2:50 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1690
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
07
Purpose
Routine Assessment
Project
WO_0459268_TV14035_2014October
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
14 0153A
Downstream MH
14 0153
Dir. of Survey
Downstream
Length Surveyed
283.1 ft.
Total Length
283.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 14 0153A to 14 0153
MH: 14 0153AMH: 14 0153downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - MAG HYDROXIDE COATING 95% INTACT0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft.0 ft. AMH - Upstream Manhole, Survey Begins - 14 0153A (02:52)15.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"18.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"50.8 ft. RFB - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES, Start63.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"66.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"114.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"114.6 ft. RFB - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish117.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"125.7 ft. RFB - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES, Start155.4 ft. RFB - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish166 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"169.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"213.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"217 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"261.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"264.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"283.1 ft. AEP - End of Pipe - AT DOWNSTREAM MANHOLE 14 0153A

Observations (22)

DistanceCodeObservation
117.6TFC
18.5TFC
166TFC
169.2TFC
213.8TFC
0MWL
0MGOMAG HYDROXIDE COATING 95% INTACT
261.8TFC
217TFC
63.2TFC
114.6TFC
0MWM
15.1TFC
50.8RFB
264.6TFC
0
114.6RFB
125.7RFB
0AMH14 0153A (02:52)
66.3TFC
283.1AEPAT DOWNSTREAM MANHOLE 14 0153A
155.4RFB

Properties (5)

custom_field_two
5
customer
LACSD
datetime
2014-12-04T02:50:55-08:00
documentation
PRO-PIPE
is_lateral_inspection
false