Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2014, 11:54 AM
  • 14 0155_14 0154_20141204_Manual.mp4

Date
12/04/2014
W/O
0459268
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00584
PipeID
P18191
Time
3:54 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1690
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
07
Purpose
Routine Assessment
Project
WO_0459268_TV14035_2014October
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
14 0154
Downstream MH
14 0155
Dir. of Survey
Upstream
Length Surveyed
221 ft.
Total Length
221 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 14 0154 to 14 0155
MH: 14 0154MH: 14 0155upstream0 ft. MSA - Survey Abandoned - DUE TO HYDROXIDE COATING BUILT UP TO MUCH ON BOTTOM OF PIPE22.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"25.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"73.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"76.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"121.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"125.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"173.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"176.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"221 ft. MGO - General Observation - MAG HYDROXIDE COATING 95% INTACT221 ft. AMH - Downstream Manhole, Survey Begins - 14 0154 (03:55)221 ft. MGO - General Observation - MANHOLE IS ABANDONED221 ft. MWM - Water Mark, 45 %of cross sectional area221 ft. MWL - Water Level, 5 %of cross sectional area

Observations (14)

DistanceCodeObservation
99.5TFC
221MSADUE TO HYDROXIDE COATING BUILT UP TO MUCH ON BOTTOM OF PIPE
147.6TFC
44.6TFC
0MGOMAG HYDROXIDE COATING 95% INTACT
0AMH14 0154 (03:55)
198.6TFC
195.7TFC
144.5TFC
0MGOMANHOLE IS ABANDONED
95.9TFC
47.7TFC
0MWM
0MWL

Properties (6)

custom_field_two
5
customer
LACSD
datetime
2014-12-04T03:54:15-08:00
documentation
PRO-PIPE
is_lateral_inspection
false
lining
MAG HYDROXIDE