Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2014, 06:19 AM
  • 14 0587_14 0586A_08122014_223301.mp4

Date
12/08/2014
W/O
453830
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00572
PipeID
P18677
Time
10:19 PM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1693
Sewer Name
14 DIVISION STREET TRUNK
City
LANCASTER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
12
Purpose
Routine Assessment
Project
WO#_453830_TV14008_December#6
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
14 0587
Downstream MH
14 0586A
Dir. of Survey
Downstream
Length Surveyed
226.4 ft.
Total Length
226.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 14 0587 to 14 0586A
MH: 14 0587MH: 14 0586Adownstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 14 0587 (22:20)0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area1.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start181.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"224 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish226.4 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 9 O'CLOCK226.4 ft. VC - Vermin Cockroach, within 8 inches of joint: YES - >50 AT MANHOLE226.4 ft. AMH - Downstream Manhole, Survey Ends - 14 0586A (22:32)

Observation photos (5)

  • Upstream Manhole, Survey Begins - 14 0587 (22:20)

    0 ft. - Upstream Manhole, Survey Begins - 14 0587 (22:20)

  • Water Level, 5 %of cross sectional area

    0 ft. - Water Level, 5 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    1.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    181.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Finish

    224 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observations (10)

DistanceCodeObservation
226.4MGOCONNECTION AT MANHOLE ACTIVE 9 O'CLOCK
226.4VC>50 AT MANHOLE
0MGOCONNECTION AT MANHOLE ACTIVE 3 O'CLOCK
181.2TFC
224DAGS
0AMH14 0587 (22:20)
1.8DAGS
226.4AMH14 0586A (22:32)
0MWL
0MWM

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2014-12-08T22:19:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false
year_laid
19810624