- Date
- 07/14/2021
- W/O
- 901370
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00303
- PipeID
- P03739
- Time
- 2:52 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9077
- Sewer Name
- 02 SANTA ANITA OUTFALL TRUNK
- City
- MONTEBELLO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- WO_901370_TV02300_JUL2021
- Sewer Type
- Siphon
- Material
- CIP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 1235
- Downstream MH
- 02 1234
- Dir. of Survey
- Downstream
- Length Surveyed
- 2.5 ft.
- Total Length
- 2.5 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 02 1235 to 02 1234 Observation photos (3)

2.2 ft. - Deposits Settled Fine, 20 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES

2.5 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.

2.5 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES