Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2021, 09:00 AM
  • 02 1780B_02 1780A_852021_020655.mp4

Date
08/05/2021
W/O
0890811
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00271
PipeID
P04123
Time
2:00 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1902
Sewer Name
02 INDIANA STREET TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
07A
Purpose
Routine Assessment
Project
20210805MDM_INDIANA_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
7.570000171661377 in.
Upstream MH
02 1780B
Downstream MH
02 1780A
Dir. of Survey
Downstream
Length Surveyed
358.7 ft.
Total Length
358.7 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
3
O&M Quick
3200
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1780B to 02 1780A
MH: 02 1780BMH: 02 1780Adownstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 2:00AM5 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBEROUS OUTER SUFACE5 ft. MGO - General Observation - 7.57" NRCP-CIPP67 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 5" - Open-40% SLUDGE126.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Active177.3 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - Open-95% SLUDGE218.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open253.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open266.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Active317.8 ft. MGP - General Photograph - MIX OF SMOOTH CIPP AND FIBOROUS CIPP325.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open358.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active358.7 ft. AMH - Downstream Manhole, Survey Ends - 2:40AM

Observation photos (3)

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBEROUS OUTER SUFACE

    5 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBEROUS OUTER SUFACE

  • General Observation - 7.57" NRCP-CIPP

    5 ft. - General Observation - 7.57" NRCP-CIPP

  • General Photograph - MIX OF SMOOTH CIPP AND FIBOROUS CIPP

    317.8 ft. - General Photograph - MIX OF SMOOTH CIPP AND FIBOROUS CIPP

Observations (16)

DistanceCodeObservation
0MWM
266.8TBActive
177.3TBDOpen-95% SLUDGE
5SSSFIBEROUS OUTER SUFACE
5MGO7.57" NRCP-CIPP
0MWL
317.8MGPMIX OF SMOOTH CIPP AND FIBOROUS CIPP
325.9TBOpen
358.7AMH2:40AM
358.2MGOConn. @ Mh, 9 O' Clock. Active
67TBDOpen-40% SLUDGE
126.1TBActive
218.2TBOpen
253.9TBOpen
0MGOConn. @ Mh, 9 O' Clock. OPEN
0AMH2:00AM

Properties (7)

custom_field_three
SPALLING FIBEROUS OUTER SURFACE
custom_field_two
4
customer
LACSD
datetime
2021-08-05T02:00:00-07:00
documentation
MARTIN,OLIVER 111,BARR,RAMERIZ
is_lateral_inspection
false
lining
CIPP