- Date
- 08/04/2021
- W/O
- 0896127
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00878
- PipeID
- P17746
- Time
- 12:39 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1900
- Sewer Name
- 30 SOUTH BAY CITIES MAIN TRUNK
- City
- HERONDO BEACH
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 30
- Page No.
- 04
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210804MDM_SOUTH_BAY_CITIES_MAIN_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Upstream MH
- 30 0043
- Downstream MH
- 30 0042
- Dir. of Survey
- Downstream
- Length Surveyed
- 300.4 ft.
- Total Length
- 300.4 ft.
- Structural Index
- 4
- Structural Quick
- 4321
- Structural Rating
- 14
- O&M Index
- 2
- O&M Quick
- 2300
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole 30 0043 to 30 0042 Observation photos (6)

0 ft. - General Observation - MAG COAT 98% START

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

8.5 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG UNDER MAG COAT

98.2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

230 ft. - General Observation - 98% OLD MAG COAT