Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 29, 2015, 08:41 AM
  • 08 0572_08 0571_20151029_005122.mp4

Date
10/29/2015
W/O
531088
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00001
PipeID
P00614
Time
1:41 AM
Certificate
U-50703-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2539
Sewer Name
08 AVALON BOULEVARD TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_531088_TV08008_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0571
Downstream MH
08 0572
Dir. of Survey
Upstream
Length Surveyed
260.9 ft.
Total Length
260.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2I11
O&M Rating
103
Overall Index
2
Overall Quick
Overall Rating
103
Pipe schematic from manhole 08 0571 to 08 0572
MH: 08 0571MH: 08 0572upstream0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Ends - 08 0572 (0151)2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish10.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"50.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"106.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"147.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"203 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"248.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"258.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start260.9 ft. MWL - Water Level, 5 %of cross sectional area260.9 ft. AMH - Downstream Manhole, Survey Begins - 08 0571 (0142)260.9 ft. MWM - Water Mark, 15 %of cross sectional area

Observations (13)

DistanceCodeObservation
12.4TFC
57.9TFC
113.7TFC
154.4TF
258.4DAGS
250.7TFC
0MWL
0AMH08 0571 (0142)
2.5DAGS
260.9VC
260.9AMH08 0572 (0151)
210TFA
0MWM

Properties (6)

additional_info
SC205601
custom_field_two
5
customer
LACSD
datetime
2015-10-29T01:41:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false