Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 29, 2015, 08:53 AM
  • 08 0573_08 0572_20151029_010238.mp4

Date
10/29/2015
W/O
531088
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00001
PipeID
P00615
Time
1:53 AM
Certificate
U-50703-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2539
Sewer Name
08 AVALON BOULEVARD TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_531088_TV08008_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0572
Downstream MH
08 0573
Dir. of Survey
Upstream
Length Surveyed
215.8 ft.
Total Length
215.8 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2G11
O&M Rating
85
Overall Index
2
Overall Quick
Overall Rating
87
Pipe schematic from manhole 08 0572 to 08 0573
MH: 08 0572MH: 08 0573upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 0573 (0202)0.1 ft. MGO - General Observation - LATERAL AT MH 12 OCLOCK0.1 ft. VC - Vermin Cockroach1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish10 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES119.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"169.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"212.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start215.8 ft. AMH - Downstream Manhole, Survey Begins - 08 0572 (0153)215.8 ft. MWL - Water Level, 5 %of cross sectional area215.8 ft. MWM - Water Mark, 15 %of cross sectional area

Observations (11)

DistanceCodeObservation
215.7MGOLATERAL AT MH 12 OCLOCK
0AMH08 0572 (0153)
46TFC
96.5TFC
0MWL
214.7DAGS
215.8AMH08 0573 (0202)
3.5DAGS
215.7VC
0MWM
205.8CL

Properties (6)

additional_info
SC205601
custom_field_two
4
customer
LACSD
datetime
2015-10-29T01:53:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false