Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 29, 2015, 06:11 AM
  • 08 0576_08 0575_20151028_222941.mp4

Date
10/28/2015
W/O
531088
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00001
PipeID
P00618
Time
11:11 PM
Certificate
U-50703-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2539
Sewer Name
08 AVALON BOULEVARD TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_531088_TV08008_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0575
Downstream MH
08 0576
Dir. of Survey
Upstream
Length Surveyed
348.1 ft.
Total Length
348.1 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
2
O&M Quick
332M
O&M Rating
148
Overall Index
2
Overall Quick
Overall Rating
149
Pipe schematic from manhole 08 0575 to 08 0576
MH: 08 0575MH: 08 0576upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 0576 (2329)0.1 ft. VC - Vermin Cockroach3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish32.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"83.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"133.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"169 ft. RFL - Roots Fine Lateral, at 02 o'clock169 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"173.8 ft. RMJ - Roots Medium Joint, from 01 to 04 o'clock, 20 %, within 8 inches of joint: YESR195 ft. RMJ - Roots Medium Joint, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YESR214.4 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR229.3 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES230.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"230.6 ft. RFL - Roots Fine Lateral, at 02 o'clock281.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"326.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"340.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start348.1 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK348.1 ft. AMH - Downstream Manhole, Survey Begins - 08 0575 (2311)348.1 ft. MWM - Water Mark, 20 %of cross sectional area348.1 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Roots Medium Joint, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YESR

    153.1 ft. - Roots Medium Joint, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YESR

Observations (21)

DistanceCodeObservation
179.1RFL
0MGOLATERAL AT MH 3 OCLOCK
0AMH08 0575 (2311)
0MWM
315.5TFA
179.1TFC
214.3TFA
66.7TFA
7.3DAGS
133.7RMJ
348.1AMH08 0576 (2329)
174.3RMJ
345.1DAGS
21.3TFC
118.8CC
0MWL
117.5TFC
264.8TFC
117.5RFL
348VC
153.1RMJ

Properties (6)

additional_info
SC205601
custom_field_two
4
customer
LACSD
datetime
2015-10-28T23:11:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false