Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 26, 2015, 11:07 AM
  • C 0287_C 0286_20151026_031955.mp4

Date
10/26/2015
W/O
525224
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00133
PipeID
P09747
Time
4:07 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2534
Sewer Name
C JOINT OUTFALL C - UNIT 6D
City
LONG BEACH, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Routine Assessment
Project
WO_525224_TV03130_SEPT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
C 0286
Downstream MH
C 0287
Dir. of Survey
Upstream
Length Surveyed
265.7 ft.
Total Length
265.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2I12
O&M Rating
106
Overall Index
2
Overall Quick
Overall Rating
106
Pipe schematic from manhole C 0286 to C 0287
MH: C 0286MH: C 0287upstream0 ft. AMH - Upstream Manhole, Survey Ends - 0287 (0419)2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish43.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"84.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"200.2 ft. RFJ - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR204.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"208.9 ft. RFJ - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR261.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start265.7 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 3 O'CLOCK265.7 ft. MGO - General Observation - CONNECTION AT MANHOLE ACTIVE 9 O'CLOCK265.7 ft. AMH - Downstream Manhole, Survey Begins - 0286 (0407)265.7 ft. MWL - Water Level, 35 %of cross sectional area265.7 ft. MWM - Water Mark, 40 %of cross sectional area

Observations (13)

DistanceCodeObservation
0MGOCONNECTION AT MANHOLE ACTIVE 3 O'CLOCK
0MGOCONNECTION AT MANHOLE ACTIVE 9 O'CLOCK
0AMH0286 (0407)
56.8RFJ
0MWL
0MWM
265.7AMH0287 (0419)
4.3DAGS
263DAGS
181.5TFC
61.3TFC
65.5RFJ
222.3TFC

Properties (6)

additional_info
SC205596
custom_field_two
4
customer
LACSD
datetime
2015-10-26T04:07:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false