Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 11, 2015, 05:25 AM
  • H 0261A_H 0261_20150910_214208.mp4

Date
09/10/2015
W/O
521014
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00171
PipeID
P10685
Time
10:25 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2682
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_521014_TV02170_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
H 0261A
Downstream MH
H 0261
Dir. of Survey
Downstream
Length Surveyed
377.9 ft.
Total Length
377.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2^00
O&M Rating
306
Overall Index
2
Overall Quick
Overall Rating
306
Pipe schematic from manhole H 0261A to H 0261
MH: H 0261AMH: H 0261downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 0261A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start17.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start54.3 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"149.2 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"157.2 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"231 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"295.8 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"304.1 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"376.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish376.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish377.9 ft. AMH - Downstream Manhole, Survey Ends - H 0261

Observations (14)

DistanceCodeObservation
17.4DAE
376.1DAE
376.1DAGS
0MWM
149.2TBC
54.3TBC
295.8TBC
304.1TBC
0MWL
157.2TBC
377.9AMHH 0261
0AMHH 0261A
231TBC
2DAGS

Properties (6)

additional_info
SC203900
custom_field_two
4
customer
LACSD
datetime
2015-09-10T22:25:26-07:00
documentation
PRO PIPE
is_lateral_inspection
false