- Date
- 07/27/2021
- W/O
- 901695
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00705
- PipeID
- P14356
- Time
- 11:24 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9048
- Sewer Name
- 18 SOUTH PLANT OUTFALL TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901695_TV18180_JUL2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0502
- Downstream MH
- 18 0501
- Dir. of Survey
- Downstream
- Length Surveyed
- 406.4 ft.
- Total Length
- 406.4 ft.
- Structural Index
- 2
- Structural Quick
- 332a
- Structural Rating
- 350
- O&M Index
- 2
- O&M Quick
- 312O
- O&M Rating
- 163
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 513
Pipe schematic from manhole 18 0502 to 18 0501 Observation photos (4)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

10.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

406.4 ft. - General Observation - ROACHES @ MH