Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2015, 08:06 AM
  • 01 0567A_01 0567_20150122_002046.mp4

Date
01/22/2015
W/O
486126
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00194
PipeID
P01055
Time
12:06 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2116
Sewer Name
01 ALAMEDA STREET EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Purpose
Routine Assessment
Project
WO_486126_TV01001_2015JANUARY
Material
NRCP
Lining Method
Segmented Panel
Shape
Circular
Height
21 in.
Upstream MH
01 0567A
Downstream MH
01 0567
Dir. of Survey
Downstream
Length Surveyed
217.7 ft.
Total Length
217.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3F11
O&M Rating
100
Overall Index
3
Overall Quick
Overall Rating
100
Pipe schematic from manhole 01 0567A to 01 0567
MH: 01 0567AMH: 01 0567downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 0567A0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - Magnesium hydroxide coating 60% start0 ft. VC - Vermin Cockroach, within 8 inches of joint: YES164.3 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Finish - DEBRIS215 ft. MGO - General Observation - Magnesium hydroxide coating 60% finish217.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0567

Observation photos (1)

  • Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS

    0 ft. - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS

Observations (9)

DistanceCodeObservation
0AMH01 0567A
217.7AMH01 0567
0MWL
0OBZDEBRIS
0MWM
215MGOMagnesium hydroxide coating 60% finish
0MGOMagnesium hydroxide coating 60% start
0VC
164.3OBZDEBRIS

Properties (6)

additional_info
SC190226
custom_field_two
4
customer
LACSD
datetime
2015-01-22T00:06:10-08:00
documentation
PRO PIPE
is_lateral_inspection
false