Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2015, 06:22 AM
  • 01 0561_01 0560_20150122_223822.mp4

Date
01/22/2015
W/O
486126
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00194
PipeID
P01048
Time
10:22 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2117
Sewer Name
01 ALAMEDA STREET EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_486126_TV01001_2015JANUARY
Sewer Type
GRAVITY
Material
NRCP
Lining Method
Segmented Panel
Shape
Circular
Height
21 in.
Upstream MH
01 0561
Downstream MH
01 0560
Dir. of Survey
Downstream
Length Surveyed
402.1 ft.
Total Length
402.1 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
240
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
240
Pipe schematic from manhole 01 0561 to 01 0560
MH: 01 0561MH: 01 0560downstream0 ft. MGO - General Observation - Magnesium hydroxide coating 30% start0 ft. AMH - Upstream Manhole, Survey Begins - 01 05610 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start399 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish399 ft. MGO - General Observation - Magnesium hydroxide coating 30% finish402.1 ft. AMH - Downstream Manhole, Survey Ends - 01 0560

Observations (8)

DistanceCodeObservation
0MGOMagnesium hydroxide coating 30% start
0AMH01 0561
0.1SAV
402.1AMH01 0560
0MWL
0MWM
399SAV
399MGOMagnesium hydroxide coating 30% finish

Properties (6)

additional_info
SC190227
custom_field_two
4
customer
LACSD
datetime
2015-01-22T22:22:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false