Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2015, 11:53 AM
  • 01 0562_01 0561_20150122_041204.mp4

Date
01/22/2015
W/O
486126
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00194
PipeID
P01049
Time
3:53 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2116
Sewer Name
01 ALAMEDA STREET EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_486126_TV01001_2015JANUARY
Sewer Type
GRAVITY
Material
NRCP
Lining Method
Segmented Panel
Shape
Circular
Height
21 in.
Upstream MH
01 0562
Downstream MH
01 0561
Dir. of Survey
Downstream
Length Surveyed
437.8 ft.
Total Length
437.8 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
258
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
258
Pipe schematic from manhole 01 0562 to 01 0561
MH: 01 0562MH: 01 0561downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 05620 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - Magnesium hydroxide coating 40% start0 ft. MWM - Water Mark, 30 %of cross sectional area3.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start435.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish435.4 ft. MGO - General Observation - Magnesium hydroxide coating 40% finish437.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0561

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH01 0562
435.4SAV
0MWL
435.4MGOMagnesium hydroxide coating 40% finish
437.8AMH01 0561
3.6SAV
0MGOMagnesium hydroxide coating 40% start
0MWM

Properties (6)

additional_info
SC190226
custom_field_two
4
customer
LACSD
datetime
2015-01-22T03:53:07-08:00
documentation
PRO PIPE
is_lateral_inspection
false