Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2021, 11:18 AM
  • 15 0471_15 0470_07192021_042307.mp4

Date
07/19/2021
W/O
901239
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00629
PipeID
P12396
Time
4:18 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9037
Sewer Name
15 SANTA ANITA OUTFALL TRUNK
City
ROSEMEAD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_901239_TV15144_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
15 0470
Downstream MH
15 0471
Dir. of Survey
Upstream
Length Surveyed
62.2 ft.
Total Length
62.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2A00
O&M Rating
24
Overall Index
2
Overall Quick
Overall Rating
24
Pipe schematic from manhole 15 0470 to 15 0471
MH: 15 0470MH: 15 0471upstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Ends - 14 04711.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish60.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start62.2 ft. MWM - Water Mark, 40 %of cross sectional area62.2 ft. MWL - Water Level, 20 %of cross sectional area62.2 ft. AMH - Downstream Manhole, Survey Begins - 14 0470

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    62.2 ft. - General Observation - ROACHES @ MH

Observations (7)

DistanceCodeObservation
0MWM
0MWL
2DAGS
60.3DAGS
62.2MGOROACHES @ MH
62.2AMH14 0471
0AMH14 0470

Properties (6)

additional_info
630069071921001
custom_field_three
RFIR/LIGHT GREASE
customer
1
datetime
2021-07-19T04:18:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false