Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 15, 2021, 05:09 AM
  • B 1184_B 1183_07142021_222451.mp4

Date
07/14/2021
W/O
901692
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01125
PipeID
P13504
Time
10:09 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8679
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_901692_TV16118_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
B 1184
Downstream MH
B 1183
Dir. of Survey
Downstream
Length Surveyed
261.5 ft.
Total Length
261.5 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole B 1184 to B 1183
MH: B 1184MH: B 1183downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 118425.8 ft. HVV - Hole Void Visible, at 02 o'clock, within 8 inches of joint: NO26 ft. FM - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES54.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO75.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES172.1 ft. FS - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES224.9 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES243.3 ft. FS - Fracture Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES261.5 ft. AMH - Downstream Manhole, Survey Ends - B 1183

Observation photos (7)

  • Hole Void Visible, at 02 o'clock, within 8 inches of joint: NO

    25.8 ft. - Hole Void Visible, at 02 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    26 ft. - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    54.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    75.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    172.1 ft. - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    224.9 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES

    243.3 ft. - Fracture Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
54.3CL
172.1FS
243.3FS
0MWM
0MWL
25.8HVV
26FM
224.9CL
0AMHB 1184
261.5AMHB 1183
75.6CL

Properties (7)

additional_info
630138071421201
custom_field_three
HOLE IN PIPE, FRACTURES
custom_field_two
1
customer
1
datetime
2021-07-14T22:09:57-07:00
documentation
PROPIPE
is_lateral_inspection
false