- Date
- 07/29/2021
- W/O
- 901263
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00812
- PipeID
- P17424
- Time
- 11:44 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9107
- Sewer Name
- 22 IRWINDALE TRUNK, SECTS 2,3,4,&5
- City
- VINCENT
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- WO_901263_TV22090_JUL2021
- Sewer Type
- Siphon
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 1052
- Downstream MH
- 22 1053
- Dir. of Survey
- Upstream
- Length Surveyed
- 61.5 ft.
- Total Length
- 61.5 ft.
- Structural Index
- 2
- Structural Quick
- 3112
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 22 1052 to 22 1053 Observation photos (3)

2.4 ft. - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES

20 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

25.6 ft. - Joint Separated Medium