Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 08:01 AM
  • 05 1280_05 1279_06182021_011312.mp4

Date
06/18/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06494
Time
1:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1280
Downstream MH
05 1279
Dir. of Survey
Downstream
Length Surveyed
337.6 ft.
Total Length
337.6 ft.
Structural Index
3
Structural Quick
423J
Structural Rating
183
O&M Index
1
O&M Quick
2115
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
190
Pipe schematic from manhole 05 1280 to 05 1279
MH: 05 1280MH: 05 1279downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12803.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES8.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO15.4 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES23.3 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES35.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES51.1 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES56 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start67 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES69.1 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"89.7 ft. RFL - Roots Fine Lateral, at 10 o'clock - 5% ROOTS89.7 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 35% ROOTS-LATERAL/OPEN118.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN214.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES256 ft. RFJ - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES269.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"271.4 ft. RFJ - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES337.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE337.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1279

Observation photos (12)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

    8.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    15.4 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    23.3 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    35.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES

    51.1 ft. - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    56 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Lateral, at 10 o'clock - 5% ROOTS

    89.7 ft. - Roots Fine Lateral, at 10 o'clock - 5% ROOTS

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    118.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    214.7 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

    256 ft. - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

    271.4 ft. - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
337.4CM
3.1FM
35.5FM
269.4TFC
0MWM
337.6MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
23.3CL
214.7RFJ
118.9TBOPEN
51.1CC
56CM
89.7RFL5% ROOTS
15.4CL
69.1TSC
337.6AMH05 1279
271.4RFJ
0MGOROACHES @ MH
8.2CL
0MWL
67RFJ
0AMH05 1280
256RFJ
89.7TFD35% ROOTS-LATERAL/OPEN

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-18T01:01:12-07:00
documentation
PROPIPE
is_lateral_inspection
false