Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 07:36 AM
  • 05 1277_05 1276_06182021_004924.mp4

Date
06/18/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06490
Time
12:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1277
Downstream MH
05 1276
Dir. of Survey
Downstream
Length Surveyed
339 ft.
Total Length
339 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
332
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
468
Pipe schematic from manhole 05 1277 to 05 1276
MH: 05 1277MH: 05 1276downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12770 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start65.9 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"70.5 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"99.4 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1", 6" - ACTIVE265.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"270.8 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"337 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish339 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE339 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE339 ft. AMH - Downstream Manhole, Survey Ends - 05 1276

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1", 6" - ACTIVE

    99.4 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1", 6" - ACTIVE

Observations (18)

DistanceCodeObservation
339CM
0AMH05 1277
0MWL
339MGOCONN @ MH 9 O'CLOCK/ACTIVE
2SSS
265.5TFC
339MGOCONN @ MH 3 O'CLOCK/ACTIVE
337SSS
65.9TSC
337DAGS
0MWM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
270.8TSC
7.5CM
70.5TSC
339AMH05 1276
99.4TBIACTIVE
2DAGS

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-18T00:36:43-07:00
documentation
PROPIPE
is_lateral_inspection
false