Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 06:27 AM
  • 05 1271_05 1270_06172021_234312.mp4

Date
06/17/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06483
Time
11:27 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1271
Downstream MH
05 1270
Dir. of Survey
Downstream
Length Surveyed
339 ft.
Total Length
339 ft.
Structural Index
4
Structural Quick
514L
Structural Rating
459
O&M Index
1
O&M Quick
211E
O&M Rating
31
Overall Index
3
Overall Quick
Overall Rating
490
Pipe schematic from manhole 05 1271 to 05 1270
MH: 05 1271MH: 05 1270downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12718.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.2 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE50.3 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"65.9 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"130.5 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE142.1 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN142.1 ft. RFC - Roots Fine Connection, at 02 o'clock151.5 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start246.3 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - DEFECTIVE-OFFSET-BROKEN/ CONN/ACTIVE266.2 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"293.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish329 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES337 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE339 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN339 ft. AMH - Downstream Manhole, Survey Ends - 05 1270

Observation photos (9)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    26.2 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    130.5 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    142.1 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Roots Fine Connection, at 02 o'clock

    142.1 ft. - Roots Fine Connection, at 02 o'clock

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    151.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - DEFECTIVE-OFFSET-BROKEN/ CONN/ACTIVE

    246.3 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - DEFECTIVE-OFFSET-BROKEN/ CONN/ACTIVE

  • Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"

    266.2 ft. - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"

Observations (21)

DistanceCodeObservation
17.3FM
0MWL
0MWM
337CM
293.8RFJ
339MGOCONN @ MH 9 O'CLOCK/ACTIVE
151.5RFJ
0AMH05 1271
65.9TSC
266.2TSC
142.1TSOPEN
50.3TSC
26.2TSACTIVE
337FM
8.6CM
339MGOCONN @ MH 3 O'CLOCK/UNKNOWN
246.3TBIDEFECTIVE-OFFSET-BROKEN/ CONN/ACTIVE
339AMH05 1270
142.1RFC
130.5TSACTIVE
329B

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-06-17T23:27:45-07:00
documentation
PROPIPE
is_lateral_inspection
false