Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 06:43 AM
  • 05 1270_05 1269_06172021_235628.mp4

Date
06/17/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06482
Time
11:43 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1270
Downstream MH
05 1269
Dir. of Survey
Downstream
Length Surveyed
339.7 ft.
Total Length
339.7 ft.
Structural Index
3
Structural Quick
413M
Structural Rating
344
O&M Index
2
O&M Quick
3124
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
355
Pipe schematic from manhole 05 1270 to 05 1269
MH: 05 1270MH: 05 1269downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12700 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES33.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES63.1 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN79.3 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 3" - CAPPED151.3 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN222.9 ft. TSD - Tap Saddle Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 55% ROOTS-LATERAL/OPEN227.2 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - OPEN259.2 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"287.1 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"337 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish337 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE339.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1269

Observation photos (11)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    13.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    33.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    63.1 ft. - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 3" - CAPPED

    79.3 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 3" - CAPPED

  • Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    151.3 ft. - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    171.6 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Saddle Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 55% ROOTS-LATERAL/OPEN

    222.9 ft. - Tap Saddle Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 55% ROOTS-LATERAL/OPEN

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - OPEN

    227.2 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - OPEN

  • Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    259.2 ft. - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    287.1 ft. - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (23)

DistanceCodeObservation
79.3TSICAPPED
259.2TSC
33.8FM
171.6TBOPEN
337DAGS
287.1TSC
151.3TSC
0AMH05 1270
227.2TSIOPEN
0MWM
2DAGS
2SSS
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
2CM
0MWL
339.7CM
339.7MGOCONN @ MH 9 O'CLOCK/ACTIVE
63.1TSOPEN
337SSS
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
13.4CL
339.7AMH05 1269
222.9TSD55% ROOTS-LATERAL/OPEN

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-17T23:43:47-07:00
documentation
PROPIPE
is_lateral_inspection
false