Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 06:56 AM
  • 05 1269_05 1268_06182021_000634.mp4

Date
06/17/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06481
Time
11:56 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1269
Downstream MH
05 1268
Dir. of Survey
Downstream
Length Surveyed
208.7 ft.
Total Length
208.7 ft.
Structural Index
3
Structural Quick
413G
Structural Rating
128
O&M Index
2
O&M Quick
2G00
O&M Rating
84
Overall Index
2
Overall Quick
Overall Rating
212
Pipe schematic from manhole 05 1269 to 05 1268
MH: 05 1269MH: 05 1268downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12690 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.6 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"29.5 ft. CC - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES37.5 ft. FM - Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES86.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN111 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.1 ft. TSI - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - ACTIVE187.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN206 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish208.7 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE208.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1268208.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

    29.5 ft. - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

    37.5 ft. - Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    86.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - ACTIVE

    114.1 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2", 6" - ACTIVE

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    187.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

Observations (17)

DistanceCodeObservation
208.7MGOCONN @ MH 3 O'CLOCK/ACTIVE
0AMH05 1269
29.5CC
187.2TBOPEN
37.5FM
2DAGS
0MWL
208.7AMH05 1268
86.8TBOPEN
2CM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
206DAGS
111TSC
114.1TSIACTIVE
6.6TSC
208.7CM
0MWM

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2021-06-17T23:56:52-07:00
documentation
PROPIPE
is_lateral_inspection
false