Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 04:34 AM
  • 05 1258_05 1257_06172021_214708.mp4

Date
06/17/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06467
Time
9:34 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
24 in.
Upstream MH
05 1258
Downstream MH
05 1257
Dir. of Survey
Downstream
Length Surveyed
306.8 ft.
Total Length
306.8 ft.
Structural Index
3
Structural Quick
413K
Structural Rating
307
O&M Index
2
O&M Quick
2K11
O&M Rating
123
Overall Index
2
Overall Quick
Overall Rating
430
Pipe schematic from manhole 05 1258 to 05 1257
MH: 05 1258MH: 05 1257downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12580 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start54.3 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YES196.2 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE245.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES304 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish304 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish306.8 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED306.8 ft. AMH - Downstream Manhole, Survey Ends - 05 1257306.8 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED306.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE

    196.2 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    245.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
306.8MGOCONN @ MH 3 O'CLOCK/CAPPED
0AMH05 1258
306.8AMH05 1257
0MWM
304DAGS
306.8MGOCONN @ MH 9 O'CLOCK/CAPPED
2.6CM
245.3FM
54.3RFJ
0MWL
196.2TBIACTIVE
2DAGS
304SSS
306.8CM
2SSS

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-17T21:34:01-07:00
documentation
PROPIPE
is_lateral_inspection
false