Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2021, 04:56 AM
  • 05 1256A_05 1256_06172021_220640.mp4

Date
06/17/2021
W/O
896358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06465
Time
9:56 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8988
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_896358_TV05332_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
24 in.
Upstream MH
05 1256A
Downstream MH
05 1256
Dir. of Survey
Downstream
Length Surveyed
206.9 ft.
Total Length
206.9 ft.
Structural Index
3
Structural Quick
443G
Structural Rating
221
O&M Index
2
O&M Quick
2G00
O&M Rating
80
Overall Index
2
Overall Quick
Overall Rating
301
Pipe schematic from manhole 05 1256A to 05 1256
MH: 05 1256AMH: 05 1256downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 1256A0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKWON0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start73.4 ft. CS - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES144.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES159.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES174.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES194.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES204 ft. MGO - General Observation - ROACHES @ MH204 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish204 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish206.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish206.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1256206.9 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED206.9 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

    73.4 ft. - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    144.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    159.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    174.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    194.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
174.8FM
0AMH05 1256A
206.9CM
206.9AMH05 1256
204MGOROACHES @ MH
206.9MGOCONN @ MH 3 O'CLOCK/CAPPED
194.7FM
144.3FM
2DAGS
204DAGS
2SSS
159.2FM
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
0MGOCONN @ MH 9 O'CLOCK/UNKWON
204SSS
73.4CS
3.7CM
0MWM
0MWL
206.9MGOCONN @ MH 9 O'CLOCK/CAPPED

Properties (7)

additional_info
630074061721201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-06-17T21:56:07-07:00
documentation
PROPIPE
is_lateral_inspection
false