- Date
- 06/17/2021
- W/O
- 896358
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00518
- PipeID
- P06465
- Time
- 9:56 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8988
- Sewer Name
- 05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
- City
- REDONDO BEACH
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- RFIR_WO_896358_TV05332_JUN2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 24 in.
- Upstream MH
- 05 1256A
- Downstream MH
- 05 1256
- Dir. of Survey
- Downstream
- Length Surveyed
- 206.9 ft.
- Total Length
- 206.9 ft.
- Structural Index
- 3
- Structural Quick
- 443G
- Structural Rating
- 221
- O&M Index
- 2
- O&M Quick
- 2G00
- O&M Rating
- 80
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 301
Pipe schematic from manhole 05 1256A to 05 1256 Observation photos (6)

3.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

73.4 ft. - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

144.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

159.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

174.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

194.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES