Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2021, 04:14 PM
  • 18 0033_18 0032_06212021_222648.mp4

Date
06/21/2021
W/O
896583
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00713
PipeID
P13849
Time
9:14 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8534
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
15
Purpose
Routine Assessment
Project
RFIR_WO_896583_TV18059_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0033
Downstream MH
18 0032
Dir. of Survey
Downstream
Length Surveyed
317.7 ft.
Total Length
317.7 ft.
Structural Index
3
Structural Quick
423L
Structural Rating
197
O&M Index
1
O&M Quick
1B00
O&M Rating
14
Overall Index
3
Overall Quick
Overall Rating
211
Pipe schematic from manhole 18 0033 to 18 0032
MH: 18 0033MH: 18 0032downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00330 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK2 ft. MGO - General Observation - MAG COAT2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES16.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"31 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.6 ft. FM - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES61.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"78 ft. RFJ - Roots Fine Joint, from 04 to 09 o'clock, within 8 inches of joint: YES82.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"91 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES117.2 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES, Start119.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"120.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"176.2 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES, Finish204.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"284.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"299.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"314.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"315 ft. MGO - General Observation - MAG COATING END315 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317.7 ft. AMH - Upstream Manhole, Survey Ends - 18 0032

Observation photos (7)

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    11 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    16.8 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    53.6 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 04 to 09 o'clock, within 8 inches of joint: YES

    78 ft. - Roots Fine Joint, from 04 to 09 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES

    91 ft. - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES, Start

    117.2 ft. - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
314.2TF
284.3TF
117.2RFJ
2MGOMAG COAT
176.2RFJ
299.2TFC
0MWL
53.6FM
0AMH18 0033
317.7AMH18 0032
82.6TFC
0MWM
61.2TFC
78RFJ
315MGOMAG COATING END
204.8TF
31TFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
16.8TBA
315SAV
2SAV
11FM
119.2TFC
91RFJ
120.1TBA

Properties (7)

additional_info
630074062121201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-06-21T09:14:49-07:00
documentation
PROPIPE
is_lateral_inspection
false