Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2021, 05:05 AM
  • 18 0019_18 0018_06222021_221909.mp4

Date
06/22/2021
W/O
896583
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00713
PipeID
P13835
Time
10:05 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9051
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
15
Purpose
Routine Assessment
Project
RFIR_WO_896583_TV18059_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0019
Downstream MH
18 0018
Dir. of Survey
Downstream
Length Surveyed
369.5 ft.
Total Length
369.5 ft.
Structural Index
3
Structural Quick
423O
Structural Rating
247
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
247
Pipe schematic from manhole 18 0019 to 18 0018
MH: 18 0019MH: 18 0018downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 00190 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES40.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES69.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"78.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"80.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES89.4 ft. FM - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES105 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES243.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"253.8 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES290.2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES293.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES303.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"305.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES369.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish369.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK369.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0018

Observation photos (10)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    13.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    40.9 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    80.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    89.4 ft. - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    105 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    253.8 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    290.2 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    293.3 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    305.3 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0AMH18 0019
2.4SAV
78.7TFC
243.4TF
0MWM
80.7CL
290.2FL
369.5MGOCONNECTION AT THE MH 9 OC'LOCK
305.3FL
40.9FL
69.7TFC
303.1TF
13.2FM
253.8CM
369.5AMH18 0018
293.3FL
89.4FM
0MWL
105CM
369.4SAV

Properties (7)

additional_info
630074062221201
custom_field_three
AGGREGATE VISIBLE/ FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-06-22T22:05:23-07:00
documentation
PROPIPE