Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 10, 2017, 10:27 AM
  • 05 1094_05 1093_10032017_022748.mp4

Date
03/10/2017
W/O
624624
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00488
PipeID
P06328
Time
2:27 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4377
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_624624_TV05328_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
05 1094
Downstream MH
05 1093
Dir. of Survey
Downstream
Length Surveyed
322.4 ft.
Total Length
322.4 ft.
Structural Index
2
Structural Quick
3824
Structural Rating
35
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
35
Pipe schematic from manhole 05 1094 to 05 1093
MH: 05 1094MH: 05 1093downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 10940 ft. MWM - Water Mark, 30 %of cross sectional area16.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES24.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"25.2 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES64.8 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES84.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES111.1 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES117.4 ft. CC - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES124.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"128.8 ft. FS - Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES176.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES214.9 ft. FS - Fracture Spiral, from 10 to 05 o'clock, within 8 inches of joint: YES226 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"230 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES240.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES251.5 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES264.4 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES279.2 ft. CC - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES309.7 ft. CM - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES322.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1093

Observation photos (15)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    16.8 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    25.2 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    64.8 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    84.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    111.1 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

    117.4 ft. - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES

    128.8 ft. - Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    176.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 10 to 05 o'clock, within 8 inches of joint: YES

    214.9 ft. - Fracture Spiral, from 10 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

    230 ft. - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    240.1 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    251.5 ft. - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    264.4 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

    279.2 ft. - Crack Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    309.7 ft. - Crack Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
0MWL
64.8CM
309.7CM
84.4CM
24.1TF
240.1CL
214.9FS
279.2CC
230FC
124.8TF
0AMH05 1094
176.1CL
264.4CM
322.4AMH05 1093
111.1FS
117.4CC
128.8FS
251.5CC
16.8CL
25.2CM
0MWM
226TF

Properties (6)

additional_info
SC306886
custom_field_two
3
customer
LACSD
datetime
2017-03-10T02:27:40-08:00
documentation
PROPIPE
is_lateral_inspection
false