Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2017, 10:38 AM
  • J 0297_J 0296_02022017_025656.mpg

Date
02/02/2017
W/O
619078
Weather
Dry
Operator/Surveyor
R,VARGAS
Sewer ID
Z00059
PipeID
P11538
Time
2:38 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4103
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
41
Purpose
Routine Assessment
Project
WO_619078_TV05169_FEB2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0297
Downstream MH
J 0296
Dir. of Survey
Downstream
Length Surveyed
419.8 ft.
Total Length
419.8 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
249
O&M Index
2
O&M Quick
2P00
O&M Rating
166
Overall Index
3
Overall Quick
Overall Rating
415
Pipe schematic from manhole J 0297 to J 0296
MH: J 0297MH: J 0296downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 02972.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAGNESIUM H.O. START2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"56.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"172.3 ft. MGP - General Photograph260 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"306.2 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"415.5 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH415.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish415.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish419.8 ft. AMH - Downstream Manhole, Survey Ends - J 0296

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    172.3 ft. - General Photograph

Observations (15)

DistanceCodeObservation
306.2TBA
419.8AMHJ 0296
415.5MGOMAGNEZIUM H.O. FINISH
24.6TBA
0MWL
0MWM
172.3MGP
2.1DAGS
415.5SAV
2.1MGOMAGNESIUM H.O. START
56.1TBA
2.1SAV
415.5DAGS
0AMHJ 0297
260TFA

Properties (6)

additional_info
SC318645
custom_field_two
3
customer
LACSD
datetime
2017-02-02T02:38:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false