Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 09:32 AM
  • 02 1227_02 1226_07132021_024729.mp4

Date
07/13/2021
W/O
901267
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00303
PipeID
P03731
Time
2:32 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9072
Sewer Name
02 SANTA ANITA OUTFALL TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_901267_TV02393_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
15 in.
Upstream MH
02 1227
Downstream MH
02 1226
Dir. of Survey
Downstream
Length Surveyed
334.5 ft.
Total Length
334.5 ft.
Structural Index
2
Structural Quick
3128
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
19
Pipe schematic from manhole 02 1227 to 02 1226
MH: 02 1227MH: 02 1226downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 12270 ft. MWL - Water Level, 5 %of cross sectional area8.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES52.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES119.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES138.7 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES142.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES235.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES254.2 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES281.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES305.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES334.5 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK334.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1226

Observation photos (9)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    8.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    52.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    119.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    138.7 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    142.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    235.4 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    254.2 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    281.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    305.7 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MWM
235.4CL
334.5MGOCONNECTION AT THE MH 3 OC'LOCK
142.4CL
281.9CL
305.7CL
119.1CM
52.3CL
8.1CL
0AMH02 1227
0MWL
254.2CL
138.7CL
334.5AMH02 1226

Properties (7)

additional_info
630074071221202
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-07-13T02:32:06-07:00
documentation
PROPIPE
is_lateral_inspection
false