Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 09:51 AM
  • 02 1225A_02 1225_07132021_030248.mp4

Date
07/13/2021
W/O
901267
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00303
PipeID
P03729
Time
2:51 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9072
Sewer Name
02 SANTA ANITA OUTFALL TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_901267_TV02393_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Rectangular
Height
27 in.
Width
15 in.
Upstream MH
02 1225A
Downstream MH
02 1225
Dir. of Survey
Downstream
Length Surveyed
320.7 ft.
Total Length
320.7 ft.
Structural Index
3
Structural Quick
3C24
Structural Rating
65
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
65
Pipe schematic from manhole 02 1225A to 02 1225
MH: 02 1225AMH: 02 1225downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 1225A78.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES85.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES120.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"209.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES221.4 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES224.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start319.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish319.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK320.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1225

Observation photos (5)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    78.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    85.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    209.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    221.4 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    224.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
319.9CM
0MWL
209.4CL
320.7AMH02 1225
224.3CM
0MWM
85.7CL
120.7TF
78.4CL
0MGOCONNECTION AT THE MH 3 OC'LOCK
221.4CL
0AMH02 1225A
319.9MGOCONNECTION AT THE MH 3 OC'LOCK

Properties (7)

additional_info
630074071221202
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-07-13T02:51:27-07:00
documentation
PROPIPE
is_lateral_inspection
false