Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2021, 09:23 AM
  • G 0185_G 0184_07262021_022805.mp4

Date
07/26/2021
W/O
901368
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01180
PipeID
P01089
Time
2:23 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8685
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
LYNWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_901368_TV01265_JUL2021
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
G 0184
Downstream MH
G 0185
Dir. of Survey
Upstream
Length Surveyed
5.4 ft.
Total Length
5.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole G 0184 to G 0185
MH: G 0184MH: G 0185upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - VIEW OF SIPHON UPLEG3.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start5.4 ft. AMH - Downstream Manhole, Survey Begins - G 01845.4 ft. MWL - Water Level, 60 %of cross sectional area5.4 ft. MGO - Reversal Inspection5.4 ft. MWM - Water Mark, 75 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
5.4DAGS
5.4MSAVIEW OF SIPHON UPLEG
0AMHG 0184
0MWL
0MGO
2.1DAGS
0MWM

Properties (7)

additional_info
630138072621201
custom_field_three
CRACK MULTIPLE
custom_field_two
3
customer
1
datetime
2021-07-26T02:23:23-07:00
documentation
PROPIPE
is_lateral_inspection
false