Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2021, 09:16 AM
  • 10_1_2_26072021_022922.mp4

Date
07/26/2021
W/O
0901376
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14817
Time
2:16 AM
Certificate
U-1014-06022543
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0320R
Sewer Name
WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Maintenance Related
Project
20210723MDM_WORSHAM_CREEK_TRUNK
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 0967
Downstream MH
18 0966
Dir. of Survey
Downstream
Length Surveyed
370.5 ft.
Total Length
370.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3212
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 18 0967 to 18 0966
MH: 18 0967MH: 18 0966downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:20AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area72.5 ft. RMC - Roots Medium Connection, from 08 to 11 o'clock, 5 %, within 8 inches of joint: NO77.4 ft. RFC - Roots Fine Connection, from 09 to 11 o'clock - 1%102.5 ft. RFC - Roots Fine Connection, from 09 to 11 o'clock - 3%161.9 ft. MWL - Water Level, 80 %of cross sectional area208.6 ft. RMC - Roots Medium Connection, from 07 to 12 o'clock, 35 %, within 8 inches of joint: NO370.5 ft. AMH - Downstream Manhole, Survey Ends - 3:10AM

Observation photos (1)

  • Roots Medium Connection, from 07 to 12 o'clock, 35 %, within 8 inches of joint: NO

    208.6 ft. - Roots Medium Connection, from 07 to 12 o'clock, 35 %, within 8 inches of joint: NO

Observations (9)

DistanceCodeObservation
102.5RFC3%
370.5AMH3:10AM
0AMH2:20AM
161.9MWL
72.5RMC
208.6RMC
77.4RFC1%
0MWM
0MWL

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
1
datetime
2021-07-26T02:16:01-07:00
documentation
MARTIN,OLIVER 111,BARR,RAMIREZ
is_lateral_inspection
false
lining
PVCP