Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 05:27 PM
  • 2_1_1_13072021_103619.mp4

Date
07/13/2021
W/O
0901549
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00593
PipeID
P12974
Time
10:27 AM
Certificate
U-415-06024039
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
I0316
Sewer Name
ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20210713DF_ARCADIA_SIERRA_MADRE_TRUNK_SEC_2_5
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0773
Downstream MH
15 0772
Dir. of Survey
Downstream
Length Surveyed
408.5 ft.
Total Length
408.5 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
243
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
246
Pipe schematic from manhole 15 0773 to 15 0772
MH: 15 0773MH: 15 0772downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:32 AM0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"84 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"94.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES - 5% ROOTS132.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"136.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"274.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"277.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"327.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN329.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 90% ROOTS-LATERAL/UNKNOWN405.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish407.5 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN407.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE408.5 ft. AMH - Downstream Manhole, Survey Ends - 10:59 AM

Observations (17)

DistanceCodeObservation
136.1TFA
0AMH10:32 AM
405.7SAV
132.8TF
408.5AMH10:59 AM
407.5MGOCONN @ MH 9 O'CLOCK/UNKNOWN
15.9TF
329.8TFD90% ROOTS-LATERAL/UNKNOWN
277.6TFC
94.6RFJ5% ROOTS
2SAV
84TF
0MWL
407.5MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
274.8TFC
327.1TFOPEN

Properties (4)

customer
1
datetime
2021-07-13T10:27:25-07:00
documentation
FRANKLIN, IGNACIO, CASTILLO
is_lateral_inspection
false