Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2021, 04:04 AM
  • 02 1392_02 1391_06092021_212259.mp4

Date
06/09/2021
W/O
891419
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00349
PipeID
P02963
Time
9:04 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8894
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_891419_TV02220_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
39 in.
Upstream MH
02 1392
Downstream MH
02 1391
Dir. of Survey
Downstream
Length Surveyed
598.5 ft.
Total Length
598.5 ft.
Structural Index
4
Structural Quick
5W3W
Structural Rating
952
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
952
Pipe schematic from manhole 02 1392 to 02 1391
MH: 02 1392MH: 02 1391downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13922 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.5 ft. MGO - General Observation - MAG COATING THROUGHOUT597.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish597.8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish598.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1391

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT

    64.5 ft. - General Observation - MAG COATING THROUGHOUT

Observations (9)

DistanceCodeObservation
2SAP
64.5MGOMAG COATING THROUGHOUT
2SRV
0MWM
0MWL
598.5AMH02 1391
597.8SAP
597.8SRV
0AMH02 1392

Properties (7)

additional_info
630069060921201
custom_field_three
VISIBLE REINFORCEMENT/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2021-06-09T21:04:39-07:00
documentation
PRO PIPE
is_lateral_inspection
false