Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2021, 08:25 AM
  • A 0355_A 0354_07062021_024937.mp4

Date
07/06/2021
W/O
896129
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00325
PipeID
P08265
Time
1:25 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8545
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
ROSEMEAD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
WO_896129_TV15003_JUN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
27 in.
Upstream MH
A 0355
Downstream MH
A 0354
Dir. of Survey
Downstream
Length Surveyed
802.1 ft.
Total Length
802.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole A 0355 to A 0354
MH: A 0355MH: A 0354downstream0 ft. AMH - Upstream Manhole, Survey Begins - A03550 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. MGO - General Observation - MAG COAT START801.2 ft. MGO - General Observation - MAG COAT END802.1 ft. AMH - Downstream Manhole, Survey Ends - A 0354

Observation photos (1)

  • General Observation - MAG COAT START

    2 ft. - General Observation - MAG COAT START

Observations (6)

DistanceCodeObservation
0AMHA0355
2MGOMAG COAT START
0MWL
802.1AMHA 0354
801.2MGOMAG COAT END
0MWM

Properties (8)

additional_info
630075070621001
custom_field_three
GREASE
custom_field_two
3
customer
1
datetime
2021-07-06T01:25:29-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
29427