Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2021, 09:09 AM
  • B 0463_B 0462_06282021_021846.mp4

Date
06/28/2021
W/O
896137
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00094
PipeID
P08976
Time
2:09 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9009
Sewer Name
B JOINT OUTFALL B - UNIT 5D
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_896137_TV16037_JUN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
60 in.
Upstream MH
B 0463
Downstream MH
B 0462
Dir. of Survey
Downstream
Length Surveyed
169.7 ft.
Total Length
169.7 ft.
Structural Index
3
Structural Quick
3F2F
Structural Rating
168
O&M Index
2
O&M Quick
412F
O&M Rating
70
Overall Index
2
Overall Quick
Overall Rating
238
Pipe schematic from manhole B 0463 to B 0462
MH: B 0463MH: B 0462downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 04632 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start70.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: NO143.1 ft. MGO - General Observation - RUN LIST STATES MH AT 144'.167 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish167.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish167.3 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish169.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED169.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED169.7 ft. AMH - Downstream Manhole, Survey Ends - B 0462

Observation photos (3)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: NO

    70.2 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: NO

Observations (14)

DistanceCodeObservation
169.7AMHB 0462
169.6MGOCONN @ MH 9 O'CLOCK/CAPPED
169.6MGOCONN @ MH 3 O'CLOCK/CAPPED
0MWL
2SAP
167SSS
0MWM
143.1MGORUN LIST STATES MH AT 144'.
70.2FL
2SSS
167.3DAGS
0AMHB 0463
2DAGS
167.3SAP

Properties (7)

additional_info
630069062821001
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2021-06-28T02:09:35-07:00
documentation
PRO PIPE
is_lateral_inspection
false