Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2017, 06:20 PM
  • 18 1072_18 1071_322017_102550.mp4

Date
03/02/2017
W/O
0624436
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00682
PipeID
P14930
Time
10:20 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7347
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20170302DF_LA_HABRA_HEIGHTS_TRUNK_SEC_5
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 1072
Downstream MH
18 1071
Dir. of Survey
Downstream
Length Surveyed
325.8 ft.
Total Length
325.8 ft.
Structural Index
3
Structural Quick
523A
Structural Rating
51
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
56
Pipe schematic from manhole 18 1072 to 18 1071
MH: 18 1072MH: 18 1071downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:25 AM0.1 ft. MWM - Water Mark, 10 %of cross sectional area0.1 ft. MWL - Water Level, 5 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.8 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES8.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open10.4 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES13.4 ft. JOM - Joint Offset Medium - 11 TO 5 O'CLOCK13.4 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES14.1 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open22.1 ft. B - Broken, from 07 to 10 o'clock, within 8 inches of joint: YES43.4 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES44.3 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open48.9 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES49.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open76 ft. CM - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES78.6 ft. JOM - Joint Offset Medium - 12 TO 5 O'CLOCK103.4 ft. JOM - Joint Offset Medium - 11 TO 5 O'CLOCK104.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open108.3 ft. B - Broken, from 01 to 05 o'clock, within 8 inches of joint: YES109.1 ft. MGP - General Photograph - BROKEN109.5 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - Active111.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES135.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES170.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open176 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open192.6 ft. CM - Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES220.1 ft. CM - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES229.8 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open233.8 ft. RFJ - Roots Fine Joint, from 09 to 12 o'clock, within 8 inches of joint: YESR - 5235.3 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"288.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES292.7 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open298.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6"315.4 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES324.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish325.8 ft. AMH - Downstream Manhole, Survey Ends - 11:11 AM

Observation photos (21)

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    4.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    10.4 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Joint Offset Medium - 11 TO 5 O'CLOCK

    13.4 ft. - Joint Offset Medium - 11 TO 5 O'CLOCK

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    13.4 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 07 to 10 o'clock, within 8 inches of joint: YES

    22.1 ft. - Broken, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    43.4 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open

    44.3 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    48.9 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    76 ft. - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Joint Offset Medium - 12 TO 5 O'CLOCK

    78.6 ft. - Joint Offset Medium - 12 TO 5 O'CLOCK

  • Joint Offset Medium - 11 TO 5 O'CLOCK

    103.4 ft. - Joint Offset Medium - 11 TO 5 O'CLOCK

  • Broken, from 01 to 05 o'clock, within 8 inches of joint: YES

    108.3 ft. - Broken, from 01 to 05 o'clock, within 8 inches of joint: YES

  • General Photograph - BROKEN

    109.1 ft. - General Photograph - BROKEN

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - Active

    109.5 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - Active

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    111.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    135.9 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

    192.6 ft. - Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    220.1 ft. - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 09 to 12 o'clock, within 8 inches of joint: YESR - 5

    233.8 ft. - Roots Fine Joint, from 09 to 12 o'clock, within 8 inches of joint: YESR - 5

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    288.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    315.4 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

Observations (39)

DistanceCodeObservation
0.1MWM
103.4JOM11 TO 5 O'CLOCK
10.4CM
170.1TFOpen
235.3TFA
109.1MGPBROKEN
13.4JOM11 TO 5 O'CLOCK
325.8AMH11:11 AM
233.8RFJ5
49.9TFOpen
104.3TFOpen
315.4CM
0AMH10:25 AM
176TFOpen
48.9CM
109.5TFDActive
292.7TFOpen
76CM
13.4CM
288.9CL
8.6TFOpen
192.6CM
78.6JOM12 TO 5 O'CLOCK
43.4CM
108.3B
111.5CL
2SSS
22.1B
298.6TF
4.8CL
135.9FL
0.1MWL
14.1TFOpen
324.1CM
229.8TFOpen
220.1CM
324.1SSS
44.3TFDOpen
2CM

Properties (6)

custom_field_three
BROKEN PIPE
custom_field_two
2
customer
LACSD
datetime
2017-03-02T10:20:35-08:00
documentation
FRANKLIN, BRAR
is_lateral_inspection
false