Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2016, 04:46 PM
  • A 1047_A 0594_322016_090409.mp4

Date
03/02/2016
W/O
0541683
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00316
PipeID
P07800
Time
8:46 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7067
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
INDUSTRY
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Capital Improvement Program Assesment
Project
20160229AM_JOA_1A_DISTRICT_21_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
A 1047
Downstream MH
A 0594
Dir. of Survey
Downstream
Length Surveyed
853.5 ft.
Total Length
853.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole A 1047 to A 0594
MH: A 1047MH: A 0594downstream0 ft. AMH - Upstream Manhole, Survey Begins - 9:03 AM0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start443 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 4"851.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish851.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish853.5 ft. AMH - Downstream Manhole, Survey Ends - 9:27 AM

Observation photos (4)

  • Water Mark, 45 %of cross sectional area

    0 ft. - Water Mark, 45 %of cross sectional area

  • Water Level, 15 %of cross sectional area

    0 ft. - Water Level, 15 %of cross sectional area

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

Observations (9)

DistanceCodeObservation
0AMH9:03 AM
443TFA
0MWM
2SAV
851.5SAV
853.5AMH9:27 AM
0MWL
851.5SSS
2SSS

Properties (7)

additional_info
RFIR INSPECTION
custom_field_three
SPALLING AND EXP. AGGREGATE
custom_field_two
3
customer
LACSD
datetime
2016-03-02T08:46:46-08:00
documentation
MIRANDA, SHADLER, FRANKLIN, MIRABAL
is_lateral_inspection
false