Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2016, 10:40 AM
  • 05 2570_05 2569_2172016_033953.mp4

Date
02/17/2016
W/O
0547039
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01131
PipeID
P25271
Time
2:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0056
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
11A
Purpose
Routine Assessment
Project
20160216MDM_COLDEN_AVENUE_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 2569
Downstream MH
05 2570
Dir. of Survey
Upstream
Length Surveyed
3 ft.
Total Length
3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 2569 to 05 2570
MH: 05 2569MH: 05 2570upstream0 ft. MSA - Survey Abandoned - UPLEG DOWNSTREAM SIPHON SOUTH1 ft. MGP - General Photograph - UPLEG DOWNSTREAM SIPHON SOUTH3 ft. MWM - Water Mark, 60 %of cross sectional area3 ft. MWL - Water Level, 60 %of cross sectional area - STANDING WATER & SLUDGE NO FLOW STOPLOG IN PLACE3 ft. AMH - Downstream Manhole, Survey Begins - 3:45AM

Observation photos (2)

  • General Photograph - UPLEG DOWNSTREAM SIPHON SOUTH

    2 ft. - General Photograph - UPLEG DOWNSTREAM SIPHON SOUTH

  • Survey Abandoned - UPLEG DOWNSTREAM SIPHON SOUTH

    3 ft. - Survey Abandoned - UPLEG DOWNSTREAM SIPHON SOUTH

Observations (5)

DistanceCodeObservation
0MWM
2MGPUPLEG DOWNSTREAM SIPHON SOUTH
0MWLSTANDING WATER & SLUDGE NO FLOW STOPLOG IN PLACE
3MSAUPLEG DOWNSTREAM SIPHON SOUTH
0AMH3:45AM

Properties (6)

additional_info
UPLEG DOWNSTREAM SIPHON SOUTH
custom_field_two
4
customer
LACSD
datetime
2016-02-17T02:40:31-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false