Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2016, 09:36 PM
  • A 0614_A 0613_2162016_134443.mp4

Date
02/16/2016
W/O
0541683
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00316
PipeID
P07819
Time
1:36 PM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7051
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
INDUSTRY
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20160216AM_JOA_1A_DISTRICT_21_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
A 0613
Downstream MH
A 0614
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole A 0613 to A 0614
MH: A 0613MH: A 0614upstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON0.1 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO0.1 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO0.1 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO2.1 ft. MWL - Water Level, 100 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - 1:43 PM2.1 ft. MGO - General Observation - AIRLINE

Observation photos (6)

  • Downstream Manhole, Survey Begins - 1:43 PM

    0 ft. - Downstream Manhole, Survey Begins - 1:43 PM

  • General Observation - AIRLINE

    0 ft. - General Observation - AIRLINE

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

    2.1 ft. - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

Observations (7)

DistanceCodeObservation
0MWL
2SSS
2SRV
2.1MSAVIEW OF THE UPLEG PIPE OF THE D/S SIPHON
2SAV
0AMH1:43 PM
0MGOAIRLINE

Properties (7)

additional_info
RFIR INSPECTION, VIEW OF THE UPLEG PIPE OF THE D/S SIPHON
custom_field_three
SEV. EXP. AGG, SPALLING, REBAR
custom_field_two
2
customer
LACSD
datetime
2016-02-16T13:36:06-08:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false