Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 12, 2016, 06:14 PM
  • 29 0429_29 0428_2122016_105238.mp4

Date
02/12/2016
W/O
0547103
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00989
PipeID
P24466
Time
10:14 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0053
Sewer Name
29 LEWIS AVENUE SEWER
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20160212SHO_LEWIS_AVENUE_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0429
Downstream MH
29 0428
Dir. of Survey
Downstream
Length Surveyed
306.7 ft.
Total Length
306.7 ft.
Structural Index
3
Structural Quick
3924
Structural Rating
35
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
35
Pipe schematic from manhole 29 0429 to 29 0428
MH: 29 0429MH: 29 0428downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 10500 ft. MWM - Water Mark, 15 %of cross sectional area8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open9.1 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES21.8 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES31 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES44.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"60.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES69.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES86 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"87.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES93.3 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES97.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"99 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES105 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES117.3 ft. CM - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES129.5 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES132.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES135.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start145.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"175.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open199.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open238.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"250.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open305.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish306.7 ft. AMH - Downstream Manhole, Survey Ends - 1130

Observation photos (13)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    9.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    21.8 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    31 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    60.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    69.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    87.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    93.3 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    99 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    105 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    117.3 ft. - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

    129.5 ft. - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    132.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    135.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
60.7CM
117.3CM
250.1TFOpen
145.9TFA
9.1CM
31CL
86TF
69.8CM
93.3CM
105CL
306.7AMH1130
305.1CM
199.6TFOpen
87.4CL
0MWL
99CM
0AMH1050
129.5CM
8TFOpen
0MWM
175.6TFOpen
132.8CL
44.1TFA
21.8CM
135.4CM
97.6TF
238.8TFC

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
LACSD
datetime
2016-02-12T10:14:35-08:00
documentation
OBREGON, MIRABEL, FRANKLIN
is_lateral_inspection
false